| CP
SERIES TECHNICAL SPECIFICATIONS |
| Adjustable
power range (CW) |
200-3500 Watts (200-3600
typical) |
| Peak pulse power |
7 kW |
| Power stability |
±2% |
| Pulse length range |
250 µsec - CW, 70 µsec
resolution |
| Repetition rate |
0-2000 Hz |
| Wavelength |
10.6 µm |
| M2 |
<2.5 (typical 2.2 0-3 kW; 2.4 3 kW and above) |
| Beam diameter
at output (1/e2) |
14 mm |
| Waist position |
0-3.0 m from output |
| Divergence |
1.5 mrad half angle |
| Pointing stability |
< ±150 µrad(< ±60 µrad typical) |
| Electrical
consumption |
34 kW at maximum power |
| Electrical
service |
400/460 VAC ± 10%; 3 phase + gnd; 50/60 Hz |
| Gas proportions |
CO2 4.3%; N2 28.8%; He 66.9% |
| Gas pressure |
400 kPa (60 psi) |
| Gas consumption |
20-70 liter/hr. (1.2 scfh) variable |
| Ambient operating
range |
10-40°C (50-104°F) |
| Relative humidity |
95% non-condensing |
| Heat load |
36.5 kW |
| Coolant temperature |
18-20°C ± 1°C (65-68°F ± 2°F) |
| Coolant pressure |
150 kPa (40 psi), differential; 400 kPa (60 psi),
absolute |
| Coolant Filter
requirements |
100 micron |
| Coolant flow
rate |
133 liters/min. minimum (35 US gal/min.) |
| Dimensions:
Head & P/S (L,W,H) |
3105 x 855 x 883 mm (122.2 x 33.6 x 34.75
in.) |
| Weight resonator
& P/S |
1200 kgs(2,646
lbs) |
| |
|